A reinforced concrete building covering a total area of 6,700m². Due to the different column grid requirements of the basement (parking area) and the two upper floors, a base isolation system was introduced between the roof of the basement and the base of the ground floor. The building is currently being revised due to the changes in CYTA‘s structure.
The New CYTA HQ
Client Architect LocationProject Type Services Provided
Design Period Construction Period Cost (€) : Cyprus Telecommunications Authority (CYTA) : D. Kuthreotis & Associates : Larnaca, Cyprus : Buildings - Offices - Advance Earthquake Engineering Solutions : Structural and Seismic (Dynamic & Time History) Analysis and Design, Advance Earthquake Engineering Solutions – Use of Base Isolation system (FPS), Structural Detailing and Specifications. : 2002 – 2004 / Design Completed : Pending : 7.500.000,00 (estimated)