Static and seismic performance evaluation of the building with the use of Pushover Analysis. Local strengthening, repair, and structural maintenance of the building, where required. The use of Pushover Analysis resulted in a significant decrease of strengthening cost.
CYTA Broadcasting Station / Radar
: Cyprus Telecommunication Authority (Cyta) : CYTA : Kionia, Troodos, Cyprus : Rehabilitation - Static and Seismic Strengthening. : Visual site Inspection, Lab Testing Monitoring, Structural and Seismic Analysis (Pushover) and Design, Evaluation of Existing Structural Strength and Capacity - Seismic Assessment and Structural - Seismic Rehabilitation and Strengthening. Value Engineering and Structural Cost Optimization. Structural Detailing, Technical Specifications and Site Supervision. : 2001 - 2002 : 2002 - 2004 (Completed) : 430.000,00 Client Architect LocationProject Type Services Provided